Hello Dev,
Just a check, can you please make sure that the logging table no is not already in use?
Also try below stuff and if possible share the results with us
1. Stop repliction for he AFVV table
2. from expert function reset everything related to the table AFVV( make sure u reset only AFVV table data)
3. in 2nd tab of ltrc tcode there are two option reset the runtime object and the option below that execute the options for the AFVV table
4. once done.... start the replication for that table with only load option --> to check if the table is able to execute atleast load...
5. once the data is loaded try to stop again the replication for the table and sstart the same again. with replication option
share you feedback....
I had faced same issue... situation was somewhat like below ;
1. we had refresh ECC system
2. didnt perform cleanup of triggeres and loggin tables from old system
3. setup the replication configuration
found the erro rmsg that you are receiving..
Thanks
Amar